Jardan

Acu Rite III Digital Measureing System Operators Manual

Description: I have Thousands of Manuals for Metal Working, Wood Working and Fabrication Machining. Please just ask if you are looking for a hard to find Manual. It would be a pleasure to get your Machine Up and Running Again through this Invaluable Information. This item will be sent to you refurbished like new. It may not have the original color cover as it is a Digitally Enhanced Quality Bound Copy. I’ve collected Vintage Manuals for a few years. I’ve read Parts of these Programming and Operations Manuals. There are So Many Possibilities. Use the information in these manuals for Operations, Operate, Program, Maintenance, Parts Lists, Examinary Training, Motion Picture for Vintage Images, Instructions, Schematics, Wiring Diagrams, Assemblies, Methods and Ideas of Machining. Please View the Following information. Pictures of the Machine Says A Thousand Words. I will search for your specific Needs Continually. I will allow you to return any information that is of No use to you. Machine Obsolescence! ACU-RITE III Digital Measuring System Operators Manual: I.M. Inventory # A-161A GeneralInformation ....................... .. ii Warrantyto the User. ...................... .. ii FCCComplianceStatement.................. .. ii SECTION 1 INTRODUCTION 1.1 How To Use This Manual 1-1 1.2 System Description 1-1 1.3 Features You Should Know About. 1-1 1.3.1 Absolute/Incremental Measurement Mode 1-1 1.3.2 Inch-to-Millimeter Direct Conversion . 1-2 1.3.3 Preset Key 1-2 1.3.4 Machine Tool Geometry (Abbe) ErrorCompensation............. .. 1.2 1.3.5 Large Scale Integrated (LSI) Circuitry. 1-2 1.3.6 L.E.D. Display 1-2 1.3.7 Auto Enable 1-2 1.3.8 Radius/Diameter 1-2 1.3.9 Tool Offset Dimension 1-2 1.3.10 Keyboard Annunciator. 1-2 1.3.11 Membrane Control Panel 1-2 1.3.12 Switchable Resolution 1-2 1.3.13OtherFeatures ................... 1-3 1.4 Specifications 1-3 1.4.1 Console 1-3 1.4.2 Scale Assemblies 1-4 SECTION 2 INSTALLATION 2.1 Installation of Console 2-1 2.1.1 General 2-1 2.1.2 Console Location 2-1 2.2 Electrical Connections 2-1 2.2.1 Internal Switch Settings 2-3 2.2.2 Switchable Radius/Diameter Feature. 2-4 SECTION 3 OPERATION 3.1 General 3-1 3.2 Control Panel Description 3-1 3.2.1 Fault Indicator 3-1 3.2.2 L.E.D. Display 3-2 3.2.3 ZERO RESET Key 3-2 3.2.4 AUTO ENABLE Key 3-2 3.2.5 PRESET Key 3-2 3.2.6 Digit Keyboard 3-2 3.2.7 CLEAR Key 3-2 3.2.8 ABS-INCR Keys 3-2 3.2.9 INCH-mm Keys 3-2 3.2.10 Plus-Minus Keys 3-2 3.2.11 Including Tool Offset Dimensions 3-3 3.3 Operating Procedures 3-3 3.3.1 Setup 3-4 3.3.2 Incremental Mode Operation 3-4 3.3.3 Preset Operation 3-4 3.3.3.1 Example Procedure A 3-5 3.3.3.2 Example Procedure B 3-6 3.3.4 Tool Offset Operation 3-6 3.3.4.1 Example Procedure A 3-6 3.3.4.2 Example Procedure B 3-6 3.3.4.3 Example Procedure C 3-7 3.3.4.4 Example Procedure D 3-7 3.3.5 Absolute Mode Operation 3-7 3.3.6 Combined-Mode Operation 3-8 3.4 How To Use Auto Enable 3-9 SECTION 4 MACHINE TOOL ERROR COMPENSATION 4.1 Why Errors Occur 4-1 4.2 How To Measure Errors 4-1 4.2.1 Abbe Error 4-1 4.2.2 Repeatability Error 4-2 4.3 Error Correction Procedure 4-3 SECTION 5 MAINTENANCE 5.1 General 5-1 5.2 Cover Removal Procedure 5-1 5.3 Keyboard Annunciator Volume Setting 5-1 5.4 Preliminary Troubleshooting 5-1 5.5 System Troubleshooting 5-1 5.6 Scale Assembly Troubleshooting (A-R/l and A-R/5) 5-5 5.7 Reading Head Removal and Replacement 5-5 ILLUSTRATIONS Figure 1-1 ACU-RITE Digital Position Readout and Scale Assemblies , 1-1 Figure 2-1 Console Electrical Connections 2-1 Figure 2-2 Internal Switch and Jumper Locations on Axis Board 2-2 Figure 2-3 Decimal Point Jumper Placement on Axis Board Viewed from Back of Counter 2-3 Figure 2-4 Triple Axis Board with High/Low 2-5 Figure 3-1 Control Panel 3-1 Figure 3-2 Representation of Tool Offset Symbols (Plus/Minus Keys) 3-3 Figure 3-3 Table Travel Polarities (Direction) 3-3 Figure 3-4 Console Status: Power On 3-4 Figure 3-5 Console Status: Zero Reset 3-4 Figure 3-6 Console Status: Fault Indicator 3-4 Figure 3-7 Workpiece for Incremental Procedure 3-4 Figure 3-8 Console Status: Preset Value Display.. 3-5 Figure 3-9 Console Status: Clearing Preset and Display 3-5 Figure 3-10 Console Status: Digital Display 3-5 Figure 3-11 Console Status: Preset Entry, Incremental Mode 3-5 Figure 3-12 Workpiece for Preset Procedure A 3-5 Figure 3-13 Workpiece for Preset Procedure B 3-6 Figure 3-14 Workpiece for Tool Offset Procedure A 3-6 Figure 3-15 Workpiece for Tool Offset Procedure B 3-7 Figure 3-16 Workpiece for Tool Offset ProcedureC ..................... 3-7 Figure 3-17 Workpiece for Tool Offset Procedure D ..................... 3-7 Figure 3-18 Console Status: Absolute Mode 3-8 Figure 3-19 Console Status: Preset Entry, Absolute Mode 3-8 Figure 3-20 Console Status: Clearing Preset in Absolute Mode 3-8 Figure 3-21 Console Status: Digital Display in Absolute Mode 3-8 Figure 3-22 Workpiece for Combined Mode Procedure ....................... 3-8 Figure 3-23 Console Status: Auto Enable TABLES Exaggerated Abbe Error Curve of Travel on a Milling Machine with an Overhanging Table 4-1 First Step in Measuring Abbe Error. .. 4-1 Second Step in Measuring Abbe Error 4-1 Error Slope Plotted in Inches 4-2 Error Sope Plotted in mm 4-2 Test Points on Display Board 5-1 Test Points on Power Supply Board 5-1 A-R/5 Scale Assembly Parts Identification 5-6 A-R/l Scale Assembly Parts Identification 5-7 Table 1-1 Display and Resolution of Switchable Resolution Setting 1-2 Table 2-1 Internal Switch Settings 2-3 Table 2-2 Round-off in mm/inch Conversion 2-4 Table 3-1 Resolutions Versus Speed 3-2 Table 4-1 Standard and Displayed Measurements Onch) 4-2 Table 4-2 Standard and Displayed Measurements (Metric) 4-2 Table 4-3 Switch Assembly SI Settings for Error Connectjon and Diameter Readout Selection 4-3 Table 5-1 System Troubleshooting 5-2 This Manual is 32 Printed Pages. Normal 0 false false false EN-US X-NONE X-NONE Normal 0 false false false EN-US X-NONE X-NONE All Manuals come Spiral Bound, Transparent Plastic Front and Back Cover. Most Products are Shipped the next day. After Much Consideration, ALL INTERNATIONAL SALES Will Be a Computer Generated .pdf E-Mail. PDF files are available upon request

Price: 18 USD

Location: Menifee, California

End Time: 2025-01-19T23:11:52.000Z

Shipping Cost: 0 USD

Product Images

Acu Rite III Digital Measureing System Operators Manual

Item Specifics

Restocking Fee: No

All returns accepted: Returns Accepted

Item must be returned within: 30 Days

Refund will be given as: Money Back

Return shipping will be paid by: Buyer

MPN: Does Not Apply

Brand: Acu-Rite

Model: III

Machine Manual: Installation, Operation, Maintenance, Tool error

Recommended

ACU-RITE ACURITE 382260101 READOUT BRACKET KIT
ACU-RITE ACURITE 382260101 READOUT BRACKET KIT

$69.99

View Details
Acu-Rite Millmate Mini-Scale End Cap Repair Kit  383106-144
Acu-Rite Millmate Mini-Scale End Cap Repair Kit 383106-144

$12.99

View Details
Bausch & LOMB 36.75.66.00 ACU RITE II Digital Position Readout
Bausch & LOMB 36.75.66.00 ACU RITE II Digital Position Readout

$119.99

View Details
ACU-RITE LINEAR ENCODER 38-34-12-01 NEW .001MM ABSOLUTE ZERO II
ACU-RITE LINEAR ENCODER 38-34-12-01 NEW .001MM ABSOLUTE ZERO II

$299.99

View Details
AcuRite EXTENSION POLE Mount 5-in-1 Pro Iris Atlas Acu-Rite Weather Station USA
AcuRite EXTENSION POLE Mount 5-in-1 Pro Iris Atlas Acu-Rite Weather Station USA

$26.99

View Details
689402-05 Anilam  Acu-Rite Mill Bracket
689402-05 Anilam Acu-Rite Mill Bracket

$149.99

View Details
Clemson Tigers NCAA Acu-Rite College Clock 8"
Clemson Tigers NCAA Acu-Rite College Clock 8"

$15.00

View Details
Acu-Rite Digital Probe Cooking Kitchen Thermometer with Pager 00278 Acurite
Acu-Rite Digital Probe Cooking Kitchen Thermometer with Pager 00278 Acurite

$20.00

View Details
ACU-RITE WIRELESS WEATHER FORECASTER 00827, NEW AND STILL SEALED IN PACKAGE
ACU-RITE WIRELESS WEATHER FORECASTER 00827, NEW AND STILL SEALED IN PACKAGE

$24.00

View Details
New, ACU RITE Weather Center w/easy mount 5-in-1 wireless sensor, 352256/01534DI
New, ACU RITE Weather Center w/easy mount 5-in-1 wireless sensor, 352256/01534DI

$80.00

View Details