Description: CMS8000 Patient Monitor IntroductionThe monitor has abundant functions that can be used for clinical monitoring with adult, pediatric and neonate. Users may select different parameter configuration according to different requirements. The monitor, power supplied by 100-240V~,50/60Hz, adopts 12.1'' color TFT LCD displaying real-time date and waveform. It can synchronously display eight-channel waveform and full monitoring parameters equipped with an optional 48mm thermal recorder. The monitor can be connected to the central monitoring system via wire or wireless network to form a network monitoring system.This device can monitor such parameters as ECG, RESP, NIBP, SpO2, and dual-channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. Its replaceable internal battery brings lot of convenient for patient moving.FunctionsStandard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP1)ECG Heart rate(HR) ECG waveform Arrhythmia and ST-segment analysis2)RESP Respiration rate(RR) Respiration waveform3)SpO2 Oxygen saturation(SpO2) Plethysmogram(PLETH) waveform Pulse rate(PR) Bar graph4)NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)5)TEMP T1, T2, TD6)IBP(optional) CH1:SYS,DIA,MAPCH2:SYS,DIA,MAPIBP waveform7)CO2(optional) EtCO2InsCO2:Inspired Minimum CO2AwRR:Air Way RespirationIt has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.Features1)12.1'' TFT color LCD, multi-language interface(English,French,German,Italian,Dutch,Russian,Portuguese,Turkish,Spanish(EU),Polish,Romania,Kazakh,Czech,Trad Chinese,Spanish(MX),Bulgarian,Chinese,Ukraine)2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.3)All-round monitor for adult, pediatric and neonate.4)With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe.5)Finish all operations by keys and knobs.6)Maximum 8-channel waveform synchronous display.7)Display 7-lead ECG waveform on one screen, cascade ECG waveform display8)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.9)Heart rate variability (HRV) analysis function10)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.11)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.12)Drug concentration calculation and titration table functions.13)One-touch printing of trend graph14)Connect to Central Monitoring System by 3G, Wi-Fi or wired mode.15)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.16)Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary).Performance▲ECGLead mode: 3-lead or 5-leadLead selection: I, II, III, aVR, aVL, aVF, VWaveform: 5-lead, dual-channel3-lead, single-channelGain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mVScan speed: 12.5mm/s, 25 mm/s, 50 mm/sHR: Measurement and alarm range: 15~300 bpmAccuracy: ±1 % or ±1 bpm, whichever is greaterAlarm accuracy: ± 2 bpmResolution: 1 bpmST-segment monitoring:Measurement and alarm range: -2.0 mV ~ +2.0 mVAccuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNCPacemaker: yes▲RESPMethod: R-F(RA-LL) Impedance Respiration rate: Measurement and alarm range: 0~150 rpmResolution: 1 rpmMeasurement accuracy: ±2 rpmAlarm accuracy: ±3 rpmApnea alarm: 10~40sScan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s▲NIBPMethod: OscillometryMode: Manual/AUTO/STAT Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutesMeasurement period in STAT mode: 5 minutesMeasurement and alarm range: 10 ~ 270 mmHgResolution: 1 mmHgCuff pressure accuracy: ±3 mmHgMeasurement accuracy:Maximal mean deviation: ±5 mmHgMaximal standard deviation: 8 mmHgOver-pressure protection:Adult mode: 297±3 mmHg Pediatric mode: 240±3 mmHg Neonatal mode: 147±3 mmHg▲SpO2Measurement and alarm range: 0 ~ 100%Resolution: 1%Measurement accuracy: 70%~100%: ±2%; 0%~69%: unspecified ▲PRMeasurement and alarm range: 25 ~ 250 bpmMeasurement accuracy: ±2 bpm or ±2%, whichever is greater▲TEMPChannel: dual-channelMeasurement and alarm range: 0 ~ 50℃Resolution: 0.1 ℃Accuracy: ±0.1 ℃▲Power supply: 100-240V~, 50/60Hz▲Safety classification: Class I, type CF defibrillation-proof applied partAccessories1)Adult fingertip SpO2 probe (5-pin)2)Adult NIBP cuff3)NIBP extension tube4)ECG lead cable5)ECG electrode6)Temperature probe7)Power cord8)User ManualPhysical characteristicDimension: 314 mm(L) × 145 mm(W) × 264 mm(H)Weight: <3.0 kg(excluding accessories)
Price: 599 USD
Location: Elk grove village,Illinois 60007-4825
End Time: 2024-09-22T01:42:25.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Brand: CONTEC
Screen Dimensions: 12.1'' TFT color LCD
Technology: Digital
Model: CMS8000
MPN: Does Not Apply
Country/Region of Manufacture: China
Monitor Parameters: Blood Pressure, Blood Pressure - NIBP, Blood Pressure - ABPM, ECG, O2, O2 - SpO2