Jardan

CONTEC E6 Portable Electrocardiograma ECG machine,12-lead ECG/EKG Machine PC SW

Description: This product is sold worldwide, if you are using it in the United States, please contact me before purchasing? E6 electrocardiograph Introduction E6 is a kind of electrocardiograph, which is able to sample 12 leads ECG signals simultaneously and print out the ECG waveform with thermal printing system. Its functions are as follows: recording and displaying ECG waveform in auto/manual mode; measuring ECG waveform parameters automatically, and automatic analysis and diagnosis; pacing ECG detection; prompt for electrode-off and out of paper; optional interface languages(Chinese/English, etc.); built-in lithium battery, powered either by AC or DC; arbitrarily select the rhythm lead to conveniently observe abnormal heart rhythm; case database management, etc. Note: The device sold to the countries and regions that have FDA certification requirement does not support automatic analysis and diagnosis function. Function 1) Adopt 7'' high-resolution color LCD, operate by touch screen and function buttons, convenient to use. 2) Sync collection for 12-lead ECG, support routine 12-lead and Cabrera-lead waveform display. Get high-quality ECG waveform via AC filter, DFT filter, EMG filter and Low-pass Filter of ECG signal. 3) Display 3/6/12 - lead ECG waveform, print mode, sensitivity, paper speed, filter status, etc. on one screen, convenient for contrastively diagnosing. 4) Power supply: AC/DC (which can adapt AC 50/60Hz), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit. 5) Support for auto 1*12, auto 2*6, auto 2*6+1, auto 3*4, auto 3*4+1, auto 4*3, auto 4*3+1, auto 6*2, auto 6*2+1, rhythm 7, rhythm 6, rhythm 5, rhythm 4, rhythm 3, rhythm 2 and manual. The printed content contains time, calibration signal, filter status and patient’s information. Information including printed waveform length, output measurement parameters, diagnostic conclusion, superposition QRS wave, histogram, trend chart, interval list, can be set, and with time print function, which meets different requirements. 6) With the functions of auto-measurement and auto-interpretation for routine ECG parameters, provide measurement results for HR, PR interval, P Duration, QRS Duration, T Duration, QT/QTc interval, P/QRS/T Axis, R(V5), S(V1) and R(V5)+S(V1), etc. and auto-diagnosis conclusion, which reduces the doctor’s burden. 7) Rhythm lead can be selected freely, convenient to observe abnormal heart rhythm. 8) The subject’s clinical information (such as, ID, Name, Age, Sex, Height, Weight, etc.) can be entered. 9) 1000 cases (3 s case is frequently used) can be stored by the built-in memory, convenient for case review and statistic. 10) In optimal DC state, up to 10-hour standby time, continuous print for more than 3-hour and print up to 1000 ECG waveform (3 s case is frequently used). 11) Multi-language (Chinese, English, Turkish, Portuguese, German, Russian and Kazakh, etc.) interface and report. 12) External printer and USB storage device can be connected. Performance Input way: Floating and defibrillation protection Lead: Standard 12 leads Patient leakage current: <10µA Input impedance: ≥100 MΩ(1Hz) Frequency response: 0.01Hz~300 Hz(-3dB) Time constant: ≥3.2s CMRR: >123 dB Filter: AC Filter(AC50/60 Hz), EMG Filter (25 Hz/35 Hz (-3 dB)), DFT Filter, Low-pass Filter Recording way: Thermal printing system Specification of recording paper: 110 mm(W)×20 m(L) high-speed thermal paper Time base selection(paper speed): 5 mm/s, 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s, 100 mm/s, error: ±5% within 0.2s~2.0s Gain control(sensitivity): 2.5、5、10、20、40、10/5、20/10 mm/mV, accuracy is ±5%; Standard sensitivity: 10 mm/mV±0.2 mm/mV Auto record: record setup according to auto record format and mode, automatically change leads, automatically measure and analyze. Rhythm record: record setup according to rhythm record format and mode, automatically measure and analyze. Manual record: record according to manual record format. Measurement parameters: HR, PR interval, P Duration, QRS Duration, T Duration, QT/QTc interval, P/QRS/T Axis, R(V5), S(V1) and R(V5)+S(V1) amplitude Product safety type: Class I type CF defibrillation-proof applied part Polarization resistance voltage: ±950 mV Noise level: ≤12 µVp-p ECG signal input sampling frequency: 32 kHz Waveform data processing sampling frequency: 1 kHz Sampling precision: 24-bit The minimum detection signal: 10 Hz, 20 µV(peak-peak value) deflected sinusoidal signal can be detected Pacing detection channel: all leads Accuracy of input signal: ±5% Amplitude quantization: ≤5µV/LSB Interchannel time deviation: <100 µs Power supply: AC: 100V~240V(50/60Hz) DC: 7.4V/5000mAh rechargeable lithium battery Degree of protection against ingress of liquid: IPX0 Working mode: continuous working Accessories Standard configuration: A lead cable A limb electrode A chest electrode A thermal recording paper A power cord An earth wire A user manual Physical characteristic Working environment Temperature: 5℃~40℃ Relative humidity: 25%~95%(non-condensing) Atmospheric pressure: 700 hPa~1060 hPa Transport and storage environment Temperature: -20 ℃~+55 ℃ Relative humidity: ≤95% Atmospheric pressure: 500 hPa~1060 hPa Dimension: 315mm(L)×200mm(W)×92mm(H) Weight: 1.7Kg About Us Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.Most of the domestic hospitals are our customers.Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you. Shipping 1.Our shipping rates include the cost of shipping, handling, packaging,custom fees are not included,buyers pay the taxes. 2.We usually shipped out the items the next business day after payment has been verified (Sat. & Sun. excluded.) Contact Us Please contact us first if you are not satisfied with the item when you receive it or haven't received item after 30 days, We will try our best to solve any problem. Open case and negative feedback is not conducive to solve the problem for both sides. hope you can understand! All emails will be answered within 24 hours on weekdays(but within 48hours on weekends).Please don't hesitate to contact us with any queries or comments about our items or your problem. Only English operating instruction,if you need any other language,please contact us! Buy safe Products The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item. If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE,TUV of Europe.The Fingertip Pulse Oximeter that is FDA 510K Approved.

Price: 599 USD

Location: QINHUANGDAO

End Time: 2024-12-05T06:13:24.000Z

Shipping Cost: 0 USD

Product Images

CONTEC E6 Portable Electrocardiograma ECG machine,12-lead ECG/EKG Machine PC SWCONTEC E6 Portable Electrocardiograma ECG machine,12-lead ECG/EKG Machine PC SWCONTEC E6 Portable Electrocardiograma ECG machine,12-lead ECG/EKG Machine PC SWCONTEC E6 Portable Electrocardiograma ECG machine,12-lead ECG/EKG Machine PC SWCONTEC E6 Portable Electrocardiograma ECG machine,12-lead ECG/EKG Machine PC SWCONTEC E6 Portable Electrocardiograma ECG machine,12-lead ECG/EKG Machine PC SWCONTEC E6 Portable Electrocardiograma ECG machine,12-lead ECG/EKG Machine PC SWCONTEC E6 Portable Electrocardiograma ECG machine,12-lead ECG/EKG Machine PC SWCONTEC E6 Portable Electrocardiograma ECG machine,12-lead ECG/EKG Machine PC SWCONTEC E6 Portable Electrocardiograma ECG machine,12-lead ECG/EKG Machine PC SWCONTEC E6 Portable Electrocardiograma ECG machine,12-lead ECG/EKG Machine PC SWCONTEC E6 Portable Electrocardiograma ECG machine,12-lead ECG/EKG Machine PC SW

Item Specifics

Restocking Fee: No

Return shipping will be paid by: Buyer

All returns accepted: Returns Accepted

Item must be returned within: 60 Days

Refund will be given as: Money Back

Brand: CONTEC

MPN: Does not apply

Number of Channels: 6

ECG & EKG Machine Type: Electrocardiograph

Application: Resting

Operation: Digital

Intended Use/Discipline: Cardiology, Emergency Medicine

Model: E6

Number of Leads: 12

Recommended

CONTEC PM50 Multi-parameter ICU Vital Signs Patient Monitor, NIBP,SPO2,PR,NEW
CONTEC PM50 Multi-parameter ICU Vital Signs Patient Monitor, NIBP,SPO2,PR,NEW

$169.00

View Details
CONTEC Handheld Veterinary Pulse Oximeter PR SPO2 Monitor+PC Software USA
CONTEC Handheld Veterinary Pulse Oximeter PR SPO2 Monitor+PC Software USA

$89.00

View Details
Digital LED Upper Arm Blood Pressure Monitor NIBP Machine,Adult cuff,BP monitor
Digital LED Upper Arm Blood Pressure Monitor NIBP Machine,Adult cuff,BP monitor

$18.99

View Details
ABPM50 Ambulatory Blood Pressure Monitor 24h NIBP Holter Upper Arm BP Machine US
ABPM50 Ambulatory Blood Pressure Monitor 24h NIBP Holter Upper Arm BP Machine US

$149.00

View Details
CONTEC 12-Channel ECG/EKG Machine Electrocardiograph,PC software,Touch Screen,CE
CONTEC 12-Channel ECG/EKG Machine Electrocardiograph,PC software,Touch Screen,CE

$299.00

View Details
Blood Pressure Monitor Digital Upper Arm Measure NIBP Heart Rate Pulse,Voice
Blood Pressure Monitor Digital Upper Arm Measure NIBP Heart Rate Pulse,Voice

$18.99

View Details
CONTEC 24 Hours ABPM50 NIBP Monitor Ambulatory Blood Pressure Holter 2 Cuffs FDA
CONTEC 24 Hours ABPM50 NIBP Monitor Ambulatory Blood Pressure Holter 2 Cuffs FDA

$145.99

View Details
CONTEC ECG90A 12-lead ECG Machine Electrocardiograph +PC Software, Printer US
CONTEC ECG90A 12-lead ECG Machine Electrocardiograph +PC Software, Printer US

$271.99

View Details
CONTEC SC12 Multi-functional Stethoscope Single Tube Doctors Nurse Cardiology
CONTEC SC12 Multi-functional Stethoscope Single Tube Doctors Nurse Cardiology

$9.99

View Details
CONTEC Touch Digital 12 channel ECG/EKG Machine Electrocardiograph PC Software
CONTEC Touch Digital 12 channel ECG/EKG Machine Electrocardiograph PC Software

$269.00

View Details