Description: Dranetz/BMI Task 8000-2/1 Taskcard PP1 Power Platform Energy Analyzer w/CT-1000's and 150's Comes with a manual and what you see in the pictures. If you don't see it, you probably wont get it. Specifications are from Dranetz and may vary slightly due to upgrades, options, or revisions this unit may or may not have. This unit is sold guaranteed working for 30-days, parts and labor, excluding freight. The Unit's Serial Number Tag Reads: Model Number: 8000-2/1 Serial Number: 8000MA063(083) Options: HUR50 Option - Harmonics/User Reports Option Items Included: PC-PP1 Software Floppy Disks Memory Card Qty. 2 CT-1000 Current Clamps - 1000 A, 600 V rms. Serial Numbers: 1000NA057(094) and 1000NA056(094) Qty. 3 CT-150 Current Clamps - 150 A, 600 V rms. Serial Numbers: 0150MA099(083), 0150MA100(083), 0150MA068(073) Qty. 2: PN: 114013-G1, Channel Measuring Intercommunications Cable - Blue Qty. 1: PN: 114013-G2, Channel Measuring Intercommunications Cable - Red Qty. 3: PN: 114013-G3, Channel Measuring Intercommunications Cable - Black Qty. 1: PN: 114013-G4, Channel Measuring Intercommunications Cable - Blue Qty. 1: PN: 114013-G5, Channel Measuring Intercommunications Cable - Yellow Qty. 2: PN: 114014-G5, Connect to Safety Ground Cable - Green Qty. 6: PN: 115227-G1, Alligator Clip Tips - Black RS-232 Cable Description: The 8000-2 is a total electrical system analyzer which enables you to find electric power inefficiencies. It combines the best features of: A true RMS Voltmeter and RMS Clamp-on Ammeter (for effective real time troubleshooting Oscilloscope (Scope Mode for real time waveform analysis An event monitor (records out-of-limit conditions for any parameter) Phase angle meter (analyzes phase imbalances) Harmonic distortion analyzer (provides harmonic information as required by IEEE 519 and IEC 555-2) Neutral-to-ground monitor Motor inrush monitor A demand and energy use analyzer But with all its power and multi-functionality, the Dranetz 8000-2 is easy to use. Generally, three types of screens appear: menu selection screens, programming screens, and data screens. Make selections from menu screens and enter numerical data for programming screens using the 8000-2's numeric keypad. Programming and data screens have an option bar containing up to six options across the bottom of the screen. Press the function key below an option to select it. Technical Features Specifications: Physical: 7" H x 13" W x 10" D (17.8 cm x 33 cm x 25.4 cm), 20.8 pounds (9.4 kg) Environmental: Operating: 5 to 45°C Storage: -20 to 55°C Humidity: 0% to 90%, non-condensing Time Clock: Crystal controlled. 1 second resolution. Time display in 24 hr format HH:MM:SS. Accurate to 60 seconds per month. Memory: 512 kbytes of standard RAM, 1 mbytes of program ROM Memory Card: 512 Kbytes to 2 Mbytes depending on the optional card memory capacity. Power Requirements: Voltage: Switch selectable; 90 - 130 or 180 - 250 V RMS Frequency: 47 - 450 Hz Consumption: 30 VA normal operation with no printing, 120 VA max while printing (not including battery charging requirements Battery Operation: Unit will also operate using a 12 V, 10 A external battery with filtering. Battery: 12 V, 2.5 Ahrs Ni-Cad pack for Uninterruptible Power Supply (UPS) operation (up to 2 hours without printing). Kept recharged while unit operates normally. Estimated life of 2 years. 3 V, 1000 mAhrs Lithium battery for data retention with an estimated life of 2 years (operational), 1 1/2 years (storage). Interfaces Specifications: Display: Type: Transflective Liquid Crystal Display (LCD) with Electroluminescent (EL) backlighting. Resolution: 240 x 128 dot matrix. Size: 4.25" x 2.27" Printer: Type: High resolution thermal graphics printer. Resolution: 320 dots per line. Speed: 1 inch per second Paper: 2.36" x 98 feet thermal paper. Report Size: Approx. 4" Serial Port: Type: One RS232D female 25-pin connector Configuration: DCE Data Rate: 300 to 9600 baud Stop Bits: 1 Parity: ODD, EVEN, or NONE Internal Modem: Compatible: Bell 103, Bell 212A, V.22, V.22 bus Responds to "AT" command set Data Rate: 300, 1200, 2400 baud (automatic) Phone Jack: RJ-11C FCC Registration: B46USA-65156-FA-E Ringer Equivalence: 0.2 A Relay Outputs: 4 relays for external access rated 120 V AC or 30 V DC at 1 amp. Rated as pilot relays. Alarm: Audible alarm of short (approx 0.1 second) or long (approx 1 second) duration to call attention to an error condition or report trigger, respectively. Measurements Specifications: Synchronization: The 8000-2 uses phase locked synchronous sampling over the frequency ranges of 46 - 64 Hz and 380 - 440 Hz. The sample clock is derived from, and is an exact multiple of, an incoming voltage signal (any valid and available voltage is used). The valid signal for locking must be periodic and greater than 30 V RMS. All accuracy specifications are valid over this frequency range. The unit is also capable of simulating synchronous sampling using an internally generated clock for input frequency in the range of 20 - 450 Hz. The user must enter this desired frequency through the configuration menu. Phase: The 8000-2 samples all eight channels simultaneously to maintain the phase relationship among them. Resolution: Presented data is always limited to the display resolution of ±1/2 count. Internal resolution of the 8000-2 allows measuring voltage steps of 0.07 volts. Channel D low range resolution is 0.007 volts. Resolution for current measurements is dependent on which CT probe and which input channel is used. Probe1: A, B, C: D: CT-10 0.002 Amps 0.0013 Amps CT-150 0.03 Amps 0.02 Amps CT-300 0.06 Amps 0.04 Amps CT-1000 0.18 Amps 0.12 Amps CT-3000 0.55 Amps 0.37 Amps Environmental: All specifications are met at 25°C. Temperature coefficient for the measured parameters is approximately 150 ppm of full scale per degree Celsius. Updating: Measured parameters are updated once per second. Voltage: Three voltage channels with a common return. One full differential voltage channel. Range: 10 - 600 V RMS AC or 10 - 600 V DC. Channel D selectable 1 - 60 V RMS or DC Crest Factor: Maximum 2 at full scale Accuracy: ±0.1% of reading ±0.01% of full scale Current: Four independent current input channels Range: 10% - 200% of full scale CT rating on A,B,C. 2% - 100% of full scale CT rating on channel D Crest Factor: Maximum 3 at full scale A,B,C. Maximum 2 at full scale channel D Accuracy: ±0.1% of reading ±0.01% of full scale, at fundamental frequency, using Dranetz CT-150, CT-1000, CT-3000 probes only Input Resistance: Voltage Input: 2 Mohms Current Input: 150 kohms Frequency: Fundamental Range: 30 - 450 Hz Accuracy: ±0.2% of reading Measurement Channels Bandwidth: DC - 3 kHz Real Power: Single Phase: Average of instantaneous power samples taken as a product of voltage and current samples. Includes sign to indicate direction. Three Phase: Calculated as the sum of three phases. Includes sign to indicate direction Accuracy: ±0.2% of reading ±0.02% of full scale at fundamental frequency. Apparent Power (VA): Single Phase: Calculated as volts RMS times amps RMS Three Phase: Calculated as vector sum of VARABC and WABC. Includes sign to indicate direction. Accuracy: ±0.2% of reading ±0.02% of full scale at fundamental frequency Power Factor: Calculated as real power divided by apparent power. Includes sign to indicate leading or lagging load current. Accuracy: ±0.02 typical Relative Power (VAR): Single Phase: Calculated as vector difference between VA and W. Includes sign to indicate direction. Three Phase: Calculated as the sum of the three phases. Includes sign to indicate direction. Accuracy: Dependent on PF value Demand: Average power during a demand interval in W, VA, or VAR Accuracy: ±0.2% of reading ±0.02% of full scale at fundamental frequency Energy: Summation of Watt-Hours for accumulated energy use Accuracy: ±0.2% of reading ±0.02% of full scale at fundamental frequency Updating: Computed parameters are updated once per second Environmental: All specifications are met at 25°C. Temperature coefficient for computed parameters is approximately 300 ppm of full scale per degree Celsius. Harmonics Specifications: Harmonics: The 8000-2 performs a harmonic analysis using a Fast Fourier Transform (FFT) algorithm. The accuracy of any given reading is dependent on several factors including amplitude of the input signal, the distortion level, and the distribution of the individual harmonic components. Updating: All harmonic related parameters are updated once every five seconds. Total Harmonic Distortion (THD): Calculated using the individual harmonic components that result from the FFT. Displacement Power Factor (DPF): A direct result of the FFT that indicated the phase relationship of voltage to current at the fundamental frequency of a given channel. This value will agree with the (true) power factor only when the signals are pure sine waves. Telephone Influence Factor (TIF): Calculated as per the ANSI/IEEE Standard 519-1981: "IEEE Guide for Harmonic Control and Reactive Compensation of Static Power Converters." Transformer Derating Factor (TDF): Calculated as per the ANSI/IEEE Standard CS57.110-1986: "Recommended Practice for Establishing Transformer Capability when Supplying Non-Sinusoidal Line Currents." CT150 Probe Specifications: Current Range: 0.2 to 150 A rms Current Range for Amplitude Accuracy: 3 to 150 A rms Phase Accuracy*: 0.2° @ 5 - 150 A rms Frequency Range: 45 Hz to 10 kHz Output Signal: 3 V rms @ 150 A rms Maximum Conductor Size: 0.47" (12 mm) Note: *: Typical at fundamental frequency. CT1000 Probe Specifications: Current Range: 1 to 1000 A rms Current Range for Amplitude Accuracy: 50 to 1000 A rms Phase Accuracy*: 0.2° @ 100 - 1000 A rms Frequency Range: 30 Hz to 50 kHz Output Signal: 3 V rms @ 1000 A rms Maximum Conductor Size: 2.17" (55 mm) Note: *: Typical at fundamental frequency. For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a $50.00 minimum for packaging, handling, and order processing. International shipping to be determined by destination. Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.: (1) Are you the end-user of this item? (2) If you are not the ultimate end-user of the item, please state the ultimate end user's name. (3) What is the ultimate country destination? 05/07/15
Price: 3480.99 USD
Location: Phoenix, Arizona
End Time: 2023-12-29T23:33:42.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
All returns accepted: ReturnsNotAccepted
Model: 8000-2
MPN: 800-2
Brand: Dranetz