Description: MTG-1900 Mechanical Watch Calibration Instrument Multi-Function Calibration Instrument Professional Clock Maintenance Tools 1pc Technical data: Measuring possibilities: Rate deviation, amplitude, beat error of mechanical watches and diagram recording of the beat noise. Beat the number: Automatic determination of all common beat number, Manual selection for less common beat number. Day difference measuring: the range of deviation is±999 sec / day, precision 1.0 sec/day. Swing measurement: Numerical display in degrees, resolution is1°,measuring range:100°to360° (the lift angle can affect the amplitude, range:30°to 70°.Under normal circumstances, the amplitude value do not exceed360°. The period of the average measurement: 2 s, 4s, 8s, 10s, 20s, 30s, 30s, 60s. Polarization (frequency error) measurement: Numerical display in milliseconds. Resolution is 0.1 milliseconds; the measuring range is 0-9.9 ms. ft Angle: the measuring range is 30°to 70°, the factory set it to 52°. Supply voltage: single-phase AC 100 V~240V±10% two-line. Measurement of bearing: 1 to 6 positions. Color graphic: blue, white, yellow, green and black five kinds of color. Use of the environment:0℃to50℃, relative humidity:0 to 80% R Shell: Light grey plastic housing Dimensions:260×11×168mm Weight:900g Operation: After turning on the switch, the instrument has started operation, every turn off, the parameters will return to factory settings, do no store the parameters that set by user. Place the watch on the signal sensor and the uplift of watch (leader) should the sheet metal. Test position can be changed freely; the hand must remove from the sensor after the test position is fixed. Green light flashing, means have received the signal of watch. For your equipment can use for a longer time,If the watch test is not been done in a long time, please pull the power switch to the OFF position. Caution: The instrument is to be installed in such a way that it is not exposed to direct sunlight or to extreme temperature60℃.The microphone should be placed at a sufficient distance from noisy machines, loudspeakers, sharp stroke sound and particularly from ultrasonic cleaning machines. The high noise will disturb signal sensing by the microphone .If the instrument is equipped with a printer then this should also be placed at a sufficient distance. Common faults and handing: 1.After insert the socket, the screen is dark. Check the switch on back cover is on the ON or OFF. 2.The instrument can enter testing state with the sound of“Di", but after placed the watch on the sensor, the instrument do not work. Check the second hand whether rotation (and amplitude must be more than 100°), the crown of watch (leading) is against at the sheet metal of sensor. 3.Blue LED light is bright, but the lines is scattered or occur many lines. Maybe the beat is mistake, adjusted the right beat (frequency) by manual selection. eBay Cross Border Trade powered by ChannelEffect
Price: 206.9 USD
Location: CN
End Time: 2025-01-04T13:18:34.000Z
Shipping Cost: 53.6 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Origin: Mainland China
UPC: Does not apply
the period of the average measuemrnt: 2s/4s/8s/10s/20s/30s/60s
Model Number: MTG-1900
Type of Tool: Vertical
voltage: single-phase AC 100~240V +/-10%
Brand: Unbranded
ft angle: the measuring range is 30~70,the factory sey it to 52
weigeht: 900g
Type: Vertical
measurement of bearing: 1~6 positions
product number: FL1601
Model: MTG-1900
dimensions: 260*11*168mm