Description: Influence factor Test item Base condition Working condition Environment temperature All parameters (23±2)°C -10°C~ 40°C Relative humidity All parameters 40%~ 60% <80% Phase-to-neutral voltage All parameters (100±1%)V 1.0V~ 1000V Phase-to-phase voltage True RMS phase-to-phase voltage (200±1%)V 1.0V~ 2000V Current True RMS current (5±1%)A 10mA~ 6000A Network frequency All parameters 50Hz±0.1Hz 40Hz~ 70Hz Phase shift Active power and active energy Cosφ=1 Cosφ: 0.2~ 1.0 Reactive power and reactive energy Sinφ=1 Sinφ: 0.2~ 1.0 Harmonic All parameters <0.1% 0.0%~ 100% Voltage unbalance All parameters <10% 0.0%~ 100% Working voltage of device All parameters DC9.8V±0.1V DC9.5V~ 10.5V External electric field, magnetic field All parameters Should be avoided Measured lead position Measured related parameters of current Tested wire at the center of clamp. Influence factor Test item Base condition Working condition Environment temperature All parameters (23±2)°C -10°C~ 40°C Relative humidity All parameters 40%~ 60% <80% Phase-to-neutral voltage All parameters (100±1%)V 1.0V~ 1000V Phase-to-phase voltage True RMS phase-to-phase voltage (200±1%)V 1.0V~ 2000V Current True RMS current (5±1%)A 10mA~ 6000A Network frequency All parameters 50Hz±0.1Hz 40Hz~ 70Hz Phase shift Active power and active energy Cosφ=1 Cosφ: 0.2~ 1.0 Reactive power and reactive energy Sinφ=1 Sinφ: 0.2~ 1.0 Harmonic All parameters <0.1% 0.0%~ 100% Voltage unbalance All parameters <10% 0.0%~ 100% Working voltage of device All parameters DC9.8V±0.1V DC9.5V~ 10.5V External electric field, magnetic field All parameters Should be avoided Measured lead position Measured related parameters of current Tested wire at the center of clamp. Power supply Rechargeable lithium-ion battery packs 9.6V, backup charger. Battery indicator Battery symbol shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute. Power consumption Current consumption of normal test 490 mA, continuous working for 10 hours. Display mode LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm. Size of clamp FR008 small sharp current clamp: 8mm×15mm; FR020 circle current clamp: 20mm×20mm; FR050 circle current clamp: 50mm×50mm. FR300R Flexible Coil Current Sensor (with Integrator) : Ф300mm Instrument dimensions L×W×H: 277.2mm × 227.5mm × 153mm. Number of channels 4U/4I. Phase-to phase voltage 1.0V~2000V. Phase-to-neutral voltage 1.0V~1000V. Current FR008 current clamp: 10mA~10.0A; FR020 current clamp: 0.10A~100A; FR050 current clamp: 1.0A~1000A; FR300R Flexible Coil Current Sensor (with Integrator) : 10A ~ 6000A Frequency 40Hz~70Hz. Parameters of electricity W, VA, Var, PF, DPF, cosφ, tanφ. Energy parameters Wh, Varh, Vah. Harmonic Order 0~50. Total harmonic distortion Order 0~50, each phase. Expert mode Yes. Number of Transient records 150 sets. Voltage flicker Yes. Starting current mode Yes, 100 seconds. 3 phases unbalance Yes. Record 300 days(simultaneous recording 20 parameters, record one point every 5 seconds). Min/Max recorded value Measurement of maximum and minimum values over a period of time. Alarm 40 different types of parameter selections, 12,800 sets alarm logs. Peak Yes. Phasor diagram display Automatically. Capacity of snapshots 60. Menu language English/Chinese. Communication USB. Automatic switching off When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off. In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute. Backlight function Yes, suitable for use at night and dark place. Weight Host: 1.6kg (with battery). FR008 small sharp current clamp: 168g×4; FR020 circle current clamp: 252g×4; FR050 circle current clamp: 463g×4; FR300R Flexible Coil Current Sensor (with Integrator) : 280g×4; Test wires and power adapter: 800g; Total weight: about 10.8kg (with packaging). Length of voltage test wire 3m. Length of current sensor wire 2m. Working temperature and humidity -10°C~40°C; below 80%Rh. Storage temperature and humidity -10°C~60°C; below 70%Rh. Input impedance Input impedance of test voltage: 1MΩ. Withstand voltage Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell. Insulation Between instrument wiring and shell ≥10MΩ. Structure Double insulation, with insulation vibration-proof sheath. Safely rules IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.
Price: 1710 USD
Location: China
End Time: 2024-08-17T08:51:00.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Brand: Unbranded
Measuring Energy Range: 1.0V~2000V
Phase: Three Phase
Display Type: Digital Only
Active power: 0.000W~9999.9KW
Current Peak: 10mA~8484A
True RMS value of phase-to-phase voltage: 1.0V~2000v
MPN: does not apply
Phase Voltage: 1.0V~2000V
Transformer K factor: 1.00~99.99
Test channels and type: 4 changels current and 4 channels voltage
Power Supply: Rechargeable lithium battery pack9.6V