Description: TLC5007 Dynamic ECG Systems IntroductionDynamic ECG Systems adopt 3-lead, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.Function1)The recorder can real-time store ECG data for 24-hour.2)Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.3)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.4)Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel.5)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.6)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.7)With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.8)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.9)With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.10)One-key print, convenient and fast to print the reports.11)Perfect case management function.12)The risk of sleep breath pause can be predicted by the unique "Sleep breath pause syndrome"analysis function.13)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.14)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac deathPerformanceLead: 3-leadRecord time: ≥24-hourPower supply: two “AA” alkaline batteriesInterface: USB2.0Sampling accuracy: 24bitSampling frequency: 250HzDynamic range: 10mVInput impedance: ≥10MΩCMR: ≥60dBGain accuracy: At all possible gain settings, the maximum amplitude error of the output is ±10%Gain stability: One minute after energizing the device, the gain change in stable ambient conditions shall not exceed 3% over a 24h period.System noise: ≤50µVp-pMultichannel crosstalk: ≤0.2mVFrequency response: The amplitude response to sinusoidal signals within the frequency range 0.05Hz to 40Hz shall be between the +3dB to -3dB of the response at 5 Hz.Minimum measure signal: 50 µVWith the function in the presence of pacemaker pulsesTiming accuracy: the overall error during 24h shall not exceed 30s.AccessoriesLead cable (1 set)ECG electrode (1 bag)USB cable(1)Software(1)Bag(1)User manual(1)Physical characteristicDimension: 111mm(L) × 61mm(W) × 25mm(H)Weight: about 105g(without batteries) The monitor is registered on the Australian Register of Therapeutic Goods(ARTG) with the code 197923 Buy Safe Product!The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.
Price: 299 USD
Location: beijing
End Time: 2024-11-29T10:22:20.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money back or replacement (buyer's choice)
Brand: CONTEC
Mounting: Handheld
Number of Channels: 3
ECG & EKG Machine Type: Holter Monitor
MPN: Does Not Apply
Operation: Digital